Fenix Yangın | Fire Suppression, Detection and Engineering Solutions

Fenix Sistem Yangın Mühendislik Sanayi ve Ticaret A.Ş. has been operating in the fire safety sector since 2011, providing engineering, equipment supply, installation, commissioning, gas filling and maintenance services, with a particular focus on gaseous fire suppression systems.

The company approaches fire protection as an engineering process rather than simply an equipment supply operation. Each project can involve risk assessment, site inspection, system selection, hydraulic calculations, technical design, equipment procurement, field installation, commissioning and ongoing maintenance.

This integrated structure allows fire suppression systems to be planned around the characteristics of the protected space, the equipment inside it, the fire risk and the operational requirements of the facility.

Fire Suppression Engineering and Project Design

Fenix Yangın’s engineering process starts with understanding the protected area and its specific fire risks. Site surveys, risk assessment, system selection, hydraulic calculations and technical drawings are developed as connected stages.

Engineering services can include:

• Site inspection and net-volume measurement
• Fire risk assessment and classification
• Suppression-agent selection
• Design concentration calculations
• Hydraulic pipe and nozzle calculations
• Pressure-relief requirements
• Pipe-routing and nozzle-layout design
• Detection-zone planning
• CAD installation drawings
• Technical specifications and material lists

The company’s current engineering documentation refers to NFPA, EN and ISO standards and includes hydraulic calculations and application-ready engineering drawings.

Gaseous Fire Suppression Systems

Gaseous suppression systems are particularly relevant to spaces where conventional water-based extinguishing could damage sensitive equipment or valuable contents.

Fenix Yangın works with several suppression technologies, including:

• FM200 systems
• Novec 1230 clean-agent systems
• CO₂ systems
• Electrical-panel micro-suppression systems
• Kitchen hood suppression systems
• Aerosol suppression systems

The appropriate technology depends on factors such as the protected room, fire risk, equipment, occupancy and operational requirements. The company’s current system information emphasizes that system selection should begin with risk and area analysis rather than with a predetermined extinguishing agent.

FM200 Fire Suppression

FM200 is a clean-agent fire suppression technology used in applications where sensitive electronic and technical equipment requires protection.

Fenix Yangın provides engineering, project design, equipment supply, installation, commissioning, gas filling and maintenance services for FM200 systems.

Potential application areas include data centers, server rooms, UPS rooms, electrical rooms and other technical spaces requiring specialized fire protection. System quantities, pipe dimensions and nozzle positions should be calculated according to the characteristics of the protected volume.

Novec 1230 Fire Suppression

Novec 1230, identified as FK-5-1-12 in the company’s current technical content, is another clean-agent technology used for specialized fire protection.

Fenix Yangın’s current product information describes Novec 1230 as a clean extinguishing agent for specialized spaces and references approvals including UL, FM, VdS and LPCB.

The technology can be considered for applications such as:

• Data centers
• Server and IT rooms
• Telecommunications facilities
• UPS and electrical rooms
• Archives
• Museums
• Other areas containing sensitive equipment or valuable contents

Fenix Yangın also provides related installation, commissioning, gas filling and maintenance services.

CO₂ Fire Suppression Systems

Carbon dioxide fire suppression systems are high-pressure solutions used for specific industrial and technical applications, particularly areas where personnel exposure can be controlled and appropriate safety procedures are implemented.

Fenix Yangın’s current system portfolio identifies CO₂ suppression for applications such as transformers, generator rooms and cable galleries.

A CO₂ system may incorporate high-pressure cylinders, distribution piping, valves, nozzles, warning devices and release-control components. Engineering design and installation therefore need to account for the characteristics of the protected facility and applicable safety requirements.

Electrical Panel Fire Suppression

Electrical and automation panels can require localized fire protection because a fire may develop within a relatively small and enclosed technical volume.

Panel-internal fire suppression systems are designed to detect and suppress a fire close to its source within the protected cabinet.

Fenix Yangın’s installation services include heat-sensitive polymer detection tubing and related suppression components for electrical panels.

Such systems can be considered for electrical cabinets, automation panels, control equipment and other localized technical enclosures.

Kitchen Hood Fire Suppression

Commercial and industrial kitchens present specific fire risks because cooking oils and fats can ignite around cooking appliances, hoods and exhaust systems.

Kitchen hood fire suppression systems are designed specifically for these environments and can be used in restaurants, hotels, industrial kitchens and food-production facilities.

Fenix Yangın’s current system portfolio includes UL 300 kitchen hood suppression and lists industrial kitchens among its application areas.

Aerosol Fire Suppression

Aerosol suppression technology provides a compact alternative for selected technical applications where conventional pressurized-cylinder and pipe-distribution systems may not be appropriate.

Fenix Yangın lists aerosol fire suppression among its current system technologies, particularly for compact technical spaces.

System selection should be based on the protected volume, equipment, fire risk and technical conditions of the installation.

Fire Suppression Equipment Supply

Reliable fire suppression depends not only on system design but also on compatible and appropriate equipment.

Fenix Yangın supplies components for gaseous suppression systems, including cylinders, valves, nozzles, activation equipment and detection-related components.

Its current equipment-supply service references UL, FM and VdS-approved equipment and original system components.

Equipment selection is coordinated with the engineering requirements of the specific installation.

Mechanical and Electrical Installation

After engineering and procurement, the system needs to be installed correctly in the field.

Fenix Yangın’s installation services include:

• Mechanical suppression piping
• Cylinder-bank installation and fixing
• Nozzle installation
• Detection-line installation
• Electrical connections
• System integration

The company’s current installation services cover FM200, Novec 1230, CO₂ and panel-internal systems across different facility types in Turkey.

System Commissioning

Installation is followed by commissioning and functional testing. During this stage, system components and release scenarios are checked to verify that the installation corresponds with the engineering design.

Fenix Yangın’s commissioning activities include solenoid testing, pressure-gauge checks, room integrity testing, detection scenarios and functional checks for different suppression technologies.

FM200, Novec 1230 and CO₂ Gas Filling

Suppression cylinders require appropriate filling and inspection procedures to remain ready for service.

Fenix Yangın provides FM200, Novec 1230 and CO₂ gas filling services, together with cylinder inspection, hydrostatic testing, nitrogen pressurization, calibrated weighing and valve-related work.

The process can include cylinder inspection, pressure testing, agent filling, nitrogen pressurization, calibrated weighing, leak checks and reinstallation.

Periodic Maintenance and Technical Service

Fire suppression systems require regular inspection and maintenance after installation. This helps ensure that the system remains operational and that relevant components continue to meet the required service conditions.

Fenix Yangın provides periodic maintenance and technical service for gaseous and automatic fire suppression systems. Current maintenance services cover FM200, Novec 1230 and CO₂ systems and include system-specific inspection and testing procedures.

Technical support can be arranged for critical facilities where continuous protection is an important operational requirement.

Data Centers and Critical Facilities

Data centers and other critical facilities require fire protection strategies that account for sensitive equipment and the need to maintain operational continuity.

Fenix Yangın identifies application areas including:

• Data centers
• Server and IT rooms
• UPS and battery rooms
• Telecommunications facilities
• Transformer and generator rooms
• Energy facilities
• Manufacturing plants
• Hospitals and healthcare facilities
• Industrial kitchens

Its data-center fire-protection content also addresses server rooms, raised-floor spaces, network rooms, suspended ceilings and generator or energy areas as separate protection zones.

An End-to-End Fire Protection Process

Fenix Yangın’s service model covers the life cycle of a fire suppression installation rather than focusing on equipment supply alone.

The process can be summarized as:

01 – Survey and Risk Analysis
The physical characteristics and fire risks of the protected space are assessed.

02 – Engineering and Design
The suppression technology is selected and hydraulic calculations and application drawings are prepared.

03 – Equipment Supply
The required cylinders, valves, nozzles and other components are supplied according to the project.

04 – Installation
Mechanical and electrical field installation is completed.

05 – Testing and Commissioning
System components and operating scenarios are tested before handover.

06 – Gas Filling and Maintenance
Cylinder filling, inspection, periodic maintenance and technical support are provided during the operational phase.

Fenix Yangın Fire Engineering

Since 2011, Fenix Sistem Yangın Mühendislik Sanayi ve Ticaret A.Ş. has developed services covering fire suppression engineering, system design, equipment supply, installation, commissioning, gas filling and maintenance.

Its portfolio includes FM200, Novec 1230, CO₂, electrical-panel suppression, kitchen hood suppression and aerosol technologies. The appropriate system is determined according to the protected area, fire risk, equipment and operational requirements.